BSFTT - KODAK RAPID ACCESS DENTAL DEVELOPER
- MSDS: BSFTT
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: KODAK RAPID ACCESS DENTAL DEVELOPER
- National Stock Number: 6525-01-273-3572
Product Identification
Product ID:KODAK RAPID ACCESS DENTAL DEVELOPER
MSDS Date:09/26/1988
FSC:6525
NIIN:01-273-3572
MSDS Number: BSFTT
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 716-722-5151
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 80-85% %
POTASSIUM SULFITE
CAS: 10117-38-1
Fraction By Weight: 5-10% %
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 1-5% %
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9394
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HYDROQUINONE (SARA III)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: 1-5% %
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9394
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:PEL 2 MG/M3 (HYDROQUINONE)
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:LOW INHALATION HAZARD FOR USUAL
INDUSTRIAL HANDLING. CAUSES EYE IRRITATION. PROLONGED OR REPEATED
SKIN CONTACT MAY CAUSE SKIN IRRITATION AND MAY CAUSE AN ALLERGIC
SKIN REACTION.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:EYE IRRITATION, SKIN IRRITATION
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP AND WATER. IF
IRRITATION PERSISTS, GET MEDICAL ATTENTION. EYES: FLUSH WITH LARGE
AMOUNTS OF WATER FOR 15 MINUTES. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:NONFLAMMABLE. USE MEDIA APPROPRIATE FOR SURROUNDING
FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
Accidental Release
Spill Release Procedures:NEUTRALIZE WITH SODIUM BISULFATE. FLUSH
MATERIAL TO ACID-FREE SEWER WITH LARGE AMOUNTS OF WATER IF ALLOWED
BY SEWER AUTHORITY.
Neutralizing Agent:SODIUM BISULFATE
Handling
Handling and Storage Precautions:AVOID CONTACT WITH STRONG ACIDS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT. TYPICALLY,
10 ROOM VOLUMES PER HOUR IS CONSIDERED GOOD VENTILATION.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS
Other Protective Equipment:THE ROUTINE USE OF NON-ALKALINE (ACID) TYPE
OF HAND CLEANER WILL HELP MINIMIZE THE POSSIBILITY OF ALLERGIC SKIN
REACTION
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
EXPECTED TO HAVE A LOW BIOLOGICAL OXYGEN DEMAND. EXPECTED TO HAVE A
HIGH POTENTIAL TO AFFECT AQUATIC SYSTEMS. EXPECTED TO HAVE A LOW
POTENTIAL TO AFFECT SECONDARY WASTE TREATMENT MICROORGANISMS, AND T
HE GERMINATION AND GROWTH OF SOME PLANTS.
Chemical Properties
HCC:B3
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.104
pH:12.2
Evaporation Rate & Reference:0.36 (N-BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, SLIGHTLY YELLOW LIQUID, ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:EXTREME TEMPERATURES
Hazardous Decomposition Products:OXIDES OF SULFUR
Disposal
Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.